Historical

ASTM E322-12

Standard Test Method for Analysis of Low-Alloy Steels and Cast Irons by Wavelength Dispersive X-Ray Fluorescence Spectrometry


1.1 This test method covers the X-ray fluorescence spectrometric analysis of low-alloy steels and cast irons for the following elements in the ranges indicated:

ElementsMass Fraction Range, %
Manganese0.20 to 1.50
Nickel0.10 to 1.00
Chromium0.10 to 1.00
Molybdenum0.04 to 0.40
Copper0.05 to 0.30
Vanadium0.03 to 0.25

Note 1—These mass fraction ranges can be extended by the use of suitable reference materials. The detection limit for the elements is lower than the listed minimum value. The ranges represent the actual levels at which this test method was tested.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


CONTENT PROVIDER
ASTM International [astm]

Others Also Bought
Standard Test Method for Measurement of Focal Spots of Industrial X-Ray Tubes by Pinhole Imaging
Standard Test Method for Measurement of Corrosion Potentials of Aluminum Alloys
Document History
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.