IEC 60332-1-2 Ed. 1.1 b:2015

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

IEC 60332-1-2:2004+A1:2015 Specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in IEC 60332-1-1.
 NOTE 1 Testing to IEC 60332-1-2 may be performed simultaneously with that to IEC 60332-1-3 if required. Recommended requirements for performance are given in Annex A. IEC 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm² total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases, the procedure given in IEC 60332-2-2 is recommended.
NOTE 2 Since the use of insulated conductor or cable which retards  flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that  wherever the risk of propagation is high, for example in long  vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample  of cable complies with the performance requirements recommended in  this standard, that a bunch of cables will behave in a similar  manner. (See IEC 60332-3 series.) Has the status of a group safety publication in accordance with IEC Guide 104.  This consolidated version consists of the first edition (2004)  and its amendment 1 (2015). Therefore, no need to order amendment in addition to this publication.


Content Provider
International Electrotechnical Commission [iec]


Others Also Bought

Tests on electric cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted ...
Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation ...
Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation ...
Document History
We have no document history for this standard.
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS