C390-10 (R2015) - Test methods, marking requirements, and energy efficiency levels for three-phase induction motors

IMPORTANT: Enable the Macros when opening the Excel worksheet showing an example of a completed energy efficiency test report for three-phase induction motors.

Intended Use

This standard establishes the test methods, marking requirements, and energy efficiency levels for three-phase induction motors. This standard is referred in Canadian, Provincial and other foreign energy efficiency regulations.

Preface

This is the fourth edition of CSA C390, Test methods, marking requirements, and energy efficiency levels for three-phase induction motors. It supersedes the previous editions, published in 1998, 1993, and 1985, under the title Energy Efficiency Test Methods for Three-Phase Induction Motors, and Preliminary Standards C390.1 and C390.2, published in 1982. This new edition was revised to expand the scope to cover efficiency levels for motors up to 500 hp, inclusion of high or premium efficiency levels, clarifications to the testing methodology, revisions to the accuracy of the testing equipment, inclusion of uncertainties for the measurements to be taken, and updates to the Annexes.

Scope

1.1
This Standard specifies the test methods and marking requirements, and references energy efficiency levels for three-phase induction motors.

Note: The test methods contained in this Standard are not limited to specific types of motors, but where this Standard is referenced in regional legislation, some specific motor types might be included or excluded from the regulations. Legislated requirements for a given jurisdiction supersede the requirements of this Standard and neither should be used without the other. See Annex D for further information on the application of these requirements.

1.2
This Standard applies to three-phase induction motors rated 0.746 kW at 1800 rpm (or equivalent) and greater. This Standard establishes minimum efficiency levels for both NEMA and IEC motor designations covered by legislated requirements. Efficiency requirements for units rated for operation at 60 Hz are defined in Tables 2 and 3. Efficiency requirements for units rated for operation at 50 Hz are defined in Tables 4 and 5.

Note: An equivalent motor is a motor with the same torque output but with different kilowatt output and speed.

1.3
In CSA standards, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

1.4
The values in SI (metric) units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.


Content Provider
CSA America, Inc. [csa]


Document History
Revises:
Revised By:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS