IEC 60034-12 Ed. 3.0 b:2016

Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors

IEC 60034-12:2016 specifies the parameters for eight designs of starting performance of single-speed three-phase 50 Hz or 60 Hz cage induction motors in accordance with IEC 60034-1 that:
 - have a rated voltage up to 1 000 V;
 - are intended for direct-on-line or star-delta starting;
 - are rated on the basis of duty type S1;
 - are constructed to any degree of protection and explosion protection. The main changes with respect to the previous edition are as follows:
 - new design letter E for extended efficiency motors, explanation of all design letters, and description of new designs NE, NEY, HE, and HEY;
 - addition of a reference to IEC 60079-7;
 - addition of a formula to calculate locked rotor current from apparent power.


Content Provider
International Electrotechnical Commission [iec]


Others Also Bought

Rotating electrical machines - Part 15: Impulse voltage withstand levels of form-wound stator coils for rotating ...
Rotating electrical machines - Part 26: Effects of unbalanced voltages on the performance of three-phase cage induction ...
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS