ANSI Z21.56-2013/CSA 4.7-2013

ANSI Z21.56-2013/CSA 4.7-2013 - Gas-fired pool heaters

Preface

This publication represents a basic standard for safe operation, substantial and durable construction, and acceptable performance of gas-fired pool heaters. It is the result of years of experience in the manufacture, testing, installation, maintenance, inspection and research on gas-fired pool heaters designed for utilization of gas. There are risks of injury to persons inherent in appliances that, if completely eliminated, would defeat the utility of the appliance. The provisions in this standard are intended to help reduce such risks while retaining the normal operation of the appliance.

Scope

1.1.1
This standard applies to newly produced pool heaters (see Part IV, Definitions), hereinafter referred to as pool heaters or appliances, constructed entirely of new, unused parts and materials, for heating non-potable water stored at atmospheric pressure, such as water in swimming pools, spas, hot tubs and similar applications:

a. For use with natural gas;

b. For use with manufactured gas;

c. For use with mixed gas;

d. For use with liquefied petroleum gases; and

e. For use with LP gas-air mixtures.

f. For installation in applications intended to temper the entire flow of the primary circulating pool loop water prior to re-entering the pool.

g. For installation in applications for pool heaters intended to temper a portion of the primary circulating loop water diverted through the pool heater by mechanical means, and then re-enter and mix with the primary circulating loop water prior to entering the pool.

1.1.2
This standard also applies to pool heaters intended for installation at a distance less than 5 ft (1.52 m) from the inside surface of a pool or spa, hereinafter referred to as close proximity heaters (see Part IV, Definitions).

1.1.3
This standard also applies to pool heaters for indoor installation with draft hoods which are factory equipped with automatic vent damper devices (see Part IV, Definitions), hereinafter referred to as vent damper devices.

1.1.4
This standard also applies to pool heaters of other than the direct vent type which are factory equipped with electrically operated or mechanically actuated automatic flue damper devices (see Part IV, Definitions), hereinafter referred to as flue damper devices.

1.1.5
If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

1.1.6
All references to psi throughout this standard are to be considered gage pressure unless otherwise specified.

1.1.7
Exhibit D contains provisions that are unique to the United States.

1.1.8
Exhibit E contains provisions that are unique to Canada.

1.1.9
Special construction provisions applicable to a water heater designed for use with an optional listed conversion kit are outlined under Exhibit F, Optional Provisions of Listed Gas Appliance Conversion Kits.

1.1.10
Exhibit G contains a list of standards referenced in this standard, and sources from which these reference standards may be obtained.


Content Provider
CSA America, Inc. [csa]


Document History
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS