ANSI/AAMI CI86:2017

Cochlear implant systems: Requirements for safety, functional verification, labeling and reliability reporting

:This standard establishes minimum requirements for those active implantable medical devices known as cochlear implants or cochlear prostheses, which are intended to treat hearing impairment by means of electrical stimulation of the cochlea. Devices that treat hearing impairment other than by including electrical stimulation of the cochlea are not covered by this standard. This standard applies to the electrical stimulation component(s) of combination devices that treat hearing impairment using multiple means, including electrical stimulation. The tests specified in this standard are industry-accepted tests and are to be carried out on samples of devices to show compliance. This standard is also applicable to non-implantable parts and accessories of the devices, including fitting and diagnostic components. General and specific requirements are provided with regard to design verification, post-implantation device testing, reliability assessment and reporting, packaging and labeling, protections of the patient associated with design issues and device malfunctions, and protections of the device associated with environmental challenges arising from transport, storage, handling during implantation, unrelatedmedical treatments, and normal use. This standard establishes minimum requirements for those active implantable medical devices known as cochlear implants or cochlear prostheses, which are intended to treat hearing impairment by means of electrical stimulation of the cochlea. Devices that treat hearing impairment other than by including electrical stimulation of the cochlea are not covered by this standard. This standard applies to the electrical stimulation component(s) of combination devices that treat hearing impairment using multiple means, including electrical stimulation. The tests specified in this standard are industry-accepted tests and are to be carried out on samples of devices to show compliance. This standard is also applicable to non-implantable parts and accessories of the devices, including fitting and diagnostic components. General and specific requirements are provided with regard to design verification, post-implantation device testing, reliability assessment and reporting, packaging and labeling, protections of the patient associated with design issues and device malfunctions, and protections of the device associated with environmental challenges arising from transport, storage, handling during implantation, unrelatedmedical treatments, and normal use.


Content Provider
Association for the Advancement of Medical Instrumentation [aami]


Others Also Bought

Implants for surgery. Active implantable medical devices. General requirements for safety, marking and for information ...
Active implantable medical devices. Particular requirements for cochlear and auditory brainstem implant systems ...
Document History
We have no document history for this standard.
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS