ANSI/ASHRAE/IESNA 90.1-1999

Energy Efficient Design of New Buildings Except Low-Rise Residential Buildings (Including Addenda B, C, D, E, F, G, I and M) (includes supplements)

The Purpose of this standard (hereafter referred to as code) is to provide minimum requirements for the energy-efficient design of buildings except low-rise residential buildings. This code provides: (a) minimum energy-efficient requirements for the design and construction of; 1. New buildings and their systems, 2. New portions of buildings and thier systems, and 3. New systems and equipment in existing buildings. (b) criteria for determining compliance with these requirements. 2.2 The provisions of this code apply to: (a0 the envelope of buildings provided that the enclosed spaces are: 1. heated by a heating system whose output capacity is greater than or equal to 3.4 Btu//h*ft -2 (10W/m-2), or 2. cooled by a cooling system whose sensible output capacity is greater than or equal to 5 Btu/h * ft-2 (15 W/m-2); (b) the following systems and equipment used in conjunction with buildings: 1. heating, ventilating, and air conditioning, 2. service water heating, 3. electric power distribution and metering provisions, 4. electric motors and belt drives, and 5. lighting. 2.3 The provisions of this code do not apply to: (a) single-family houses, multi-family structures of three stories or fewer above grade, manufactured houses (mobile homes), and manufactured houses (modular), (b) buildings that do not use either electricity or fossil fuel, or (c) equipment and portions of building systems that use energy primarily to provide for industrial manufacturing or commercial processes. 2.4 Where specifically noted in this code, certain buildings or elements of buildings shall be exempt. 2.5 This code shall not be used to circumvent any safety, health or environmental requirements. The Power ISC represents a reduction of scope for Section 8, Power. Dropped from the section were requirements for electrical metering, harmonic losses, and transformers. Section 8 now consists of requirements for allowable voltage drop on feeder circuits and requirements for drawings and manual of the completed electrical system. *Note: Independent Substantive Changes denote limited changes to the previous public review draft.


Content Provider
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. [ashrae]


Others Also Bought

Energy Standard for Buildings Except Low-Rise Residential Buildings, SI Edition
Ventilation for Acceptable Indoor Air Quality (Includes Errata sheet and Interpretation 02 to ANSI/ASHRAE Standard ...
Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings
Document History
We have no document history for this standard.
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS