Historical

ASTM B280-08

Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service


1.1 This specification establishes the requirements for seamless copper tube intended for use in the connection, repairs, or alternations of air conditioning or refrigeration units in the field.

Note 1—Fittings used for soldered or brazed connections in air conditioning and refrigeration systems are described in ASME Standard B16.22.

Note 2—The assembly of copper tubular systems by soldering is described in Practice B 828.

Note 3—Solders for joining copper tubular systems are described in Specification B 32. The requirements for acceptable fluxes for these systems are described in Specification B 813.

1.2 The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified:

Copper
UNS No.
Previously Used
Designation
Description
C10200OFOxygen free without
residual deoxidants
C12000DLPPhosphorus deoxidized,
low residual phosphorus
C12200DHPPhosphorus deoxidized,
high residual phosphorus

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4 The following hazard statement pertains only to the test method described in Section 18.2.4 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


CONTENT PROVIDER
ASTM International [astm]

Others Also Bought
Standard Specification for Seamless Copper Tube in Coils
Standard Specification for Seamless Copper Tube for Medical Gas Systems
Standard Specification for Seamless Copper Tube, Bright Annealed
Document History
Revises:
Revised By:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.