Historical

ASTM B490-92(2008)e1

Standard Practice for Micrometer Bend Test for Ductility of Electrodeposits

1.1 This practice describes a procedure for measuring the ductility of electrodeposited foils.

1.2 This practice is suitable only for the evaluation of electrodeposits having low ductility.

1.3 The obtained ductility values must only be considered semi-quantitative because this test has a significant operator dependence.

1.4 This practice is best used for in-house process control where measurements are always made by the same operator. A change in ductility value can be used as an indication of possible changes in the electroplating solution.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

CONTENT PROVIDER
ASTM International [astm]

Others Also Bought
Standard Practice for Stitches and Seams
Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
Standard Test Methods for Rockwell Hardness of Metallic Materials <a href="#fn00002"></a>
Included in Packages
This standard is not included in any packages.
Document History
Revises:
Revised By:
Amendments & Corrections
We have no amendments or corrections for this standard.