Standard Guide for Heated System Surface Conditions That Produce Contact Burn Injuries
1.1 This guide covers a process for the determination of acceptable surface operating conditions for heated systems. The human burn hazard is defined, and methods are presented for use in the design or evaluation of heated systems to prevent serious injury from contact with the exposed surfaces.
1.2 Values stated in SI units are to be regarded as standard.
1.3 The maximum acceptable temperature for a particular surface is derived from an estimate of the possible or probable contact time, the surface system configuration, and the level of injury deemed acceptable for a particular situation.
1.4 For design purposes, the probable contact time for industrial situations has been established at 5 s. For consumer products, a longer (60-s) contact time has been proposed by Wu (1) and others to reflect the slower reaction times for children, the elderly, or the infirm.
1.5 The maximum level of injury recommended here is that causing first degree burns on the average subject. This type of injury is reversible and causes no permanent tissue damage. For cases where more severe conditions are mandated (by space, economic, exposure probability, or other outside considerations), this guide may be used to establish a second, less desirable injury level (second degree burns), where some permanent tissue damage can be permitted. At no time, however, are conditions that produce third degree burns recommended.
1.6 This guide addresses the skin contact temperature determination for passive heated surfaces only. The guidelines contained herein are not applicable to chemical, electrical, or other similar hazards that provide a heat generation source at the location of contact.
1.7 A bibliography of human burn evaluation studies and surface hazard measurement is provided in the list of references at the end of this guide (1-16).
Please first log in with a verified email before subscribing to alerts.
Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
ADD ALERT
Already Subscribed to this document.
Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
PDF DOCUMENT FORMAT
Documents sold on the ANSI Webstore are in electronic Adobe Acrobat PDF format , however some ISO and IEC standards are available from Amazon in hard copy format.
DRM PROTECTED DOCUMENTS
Some PDF files are protected by Digital Rights Management (DRM) at the request of the copyright holder. You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Some copyright holders may impose other restrictions that limit document printing and copy/paste of documents.
NON PRINTABLE DOCUMENTS
Those documents cannot be printed at the request of the copyright holder.
We have no amendments or corrections for this standard.
Are the documents at the ANSI Webstore in electronic Adobe Acrobat PDF format only?
Documents sold on the ANSI Standards Store are in electronic Adobe Acrobat PDF format.however some ISO and IEC standards are available from Amazon in hard copy format.
STANDARDS SUBSCRIPTIONS
This standard is also available to be included in Standards Subscriptions. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards.
Subscription pricing is determined by: the specific standard(s) or collections of standards, the number of locations accessing the standards, and the number of employees that need access.