Customer Service:
Mon - Fri: 8:30 am - 6 pm EST

 Most recent

ASTM C840-23

Standard Specification for Application and Finishing of Gypsum Board

1.1 This specification covers the minimum requirements for the methods of application and finishing of gypsum board, including related items and accessories to interior walls and ceilings and to exterior soffits.

1.2 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories.

1.2.1 Where this specification is more stringent (size or thickness of framing: size and spacing of fasteners) than the fire-rated construction, this specification shall govern.

1.3 Where sound control is required for a gypsum board assembly, details of construction shall be in accordance with reports of acoustical tests of assemblies that have met the required acoustical values.

1.4 Unheated spaces above gypsum board ceilings shall be properly ventilated (see Appendix X2).

1.5 The various application systems are located in the following sections:

I

Application of Single-ply Gypsum Board to Wood Framing Members

8

II

Application of Two-ply Gypsum Board to Wood Framing Members

9

III

Application of Gypsum Board by Adhesive Nail-on to Wood Framing
Members

10

IV

Semi-solid Gypsum Board Partitions

11

V

Solid Gypsum Board Partitions

12

VI

Application of Gypsum Board with Adhesives to Interior Masonry or
Concrete Walls

13

VII

Application of Gypsum Board to Rigid Foam Insulation

14

VIII

Application of Gypsum Board to Steel Framing and Furring

15

IX

Arches and Bending Radii

16

X

Application of Gypsum Board to Receive Tile by Adhesive Application

17

XI

Application of Exterior Gypsum Soffit Board or Other Gypsum Board for Use in Exterior Soffits

18

XII

Floating Interior Angles

19

XIII

Control (Expansion) Joints

20

XIV

Foil-backed Gypsum Board

21

XV

Application of Vinyl Faced Gypsum Board

22

1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.7 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.

1.8 The following precautionary caveat pertains only to Sections 6 – 26. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

For specific precautionary statements, see 4.1.1, 4.1.2, and 24.5.

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


Content Provider
ASTM International [astm]


Others Also Bought

Standard Practice for Application of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas ...
Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Prod ...
Standard Practice for Installation of Metal Ceiling Suspension Systems for<brk/> Acoustical Tile and Lay-In P ...
Document History
Revises:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS