Standard Test Method for Elements in Water by Inductively Coupled Plasma-Mass Spectrometry
1.1 This test method covers the determination of dissolved elements in ground water, surface water, and drinking water. It may also be used for the determination of total-recoverable elements in these waters as well as wastewater.
1.2 This test method should be used by analysts experienced in the use of inductively coupled plasma-mass spectrometry (ICP-MS), the interpretation of spectral and matrix interferences and procedures for their correction.
1.3 It is the user's responsibility to ensure the validity of the test method for waters of untested matrices.
1.4 Table 1 lists elements for which the test method applies, with recommended masses and typical estimated instrumental detection limits using conventional pneumatic nebulization. Actual working detection limits are sample dependent and, as the sample matrix varies, these detection limits may also vary. In time, other elements may be added as more information becomes available and as required.
1.4.1 This method covers the analysis of mine dewatering groundwater and wastewater effluent in the range of 2-120 μg/L dissolved antimony and 3-200 μg/L dissolved arsenic.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Please first log in with a verified email before subscribing to alerts.
Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
ADD ALERT
Already Subscribed to this document.
Your Alert Profile lists the documents that will be monitored. If the document is revised or amended, you will be notified by email. You may delete a document from your Alert Profile at any time. To add a document to your Profile Alert, search for the document and click “alert me”.
PDF DOCUMENT FORMAT
Documents sold on the ANSI Webstore are in electronic Adobe Acrobat PDF format , however some ISO and IEC standards are available from Amazon in hard copy format.
DRM PROTECTED DOCUMENTS
Some PDF files are protected by Digital Rights Management (DRM) at the request of the copyright holder. You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Some copyright holders may impose other restrictions that limit document printing and copy/paste of documents.
NON PRINTABLE DOCUMENTS
Those documents cannot be printed at the request of the copyright holder.
We have no amendments or corrections for this standard.
Are the documents at the ANSI Webstore in electronic Adobe Acrobat PDF format only?
Documents sold on the ANSI Standards Store are in electronic Adobe Acrobat PDF format.however some ISO and IEC standards are available from Amazon in hard copy format.
STANDARDS SUBSCRIPTIONS
This standard is also available to be included in Standards Subscriptions. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards.
Subscription pricing is determined by: the specific standard(s) or collections of standards, the number of locations accessing the standards, and the number of employees that need access.