ASTM D888-05

Standard Test Methods for Dissolved Oxygen in Water

1.1 These test methods cover the determination of dissolved oxygen in water. Three test methods are given as follows:

Range, mg/LSections
Test Method A-Titrimetric Procedure-High Level>1.08 to 15
Test Method B-Instrumental Probe Procedure0.05 to 2016 to 25
Test Method C-Luminescence-based Sensor0.05 to 2026 to 29

1.2 The precision of Test Methods A and B was carried out using a saturated sample of reagent water. It is the user's responsibility to ensure the validity of the test methods for waters of untested matrices.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Note 17.


Content Provider
ASTM International [astm]


Others Also Bought

Standard Test Methods for Low-Level Dissolved Oxygen in Water
Fire safety engineering -- Part 1: Application of fire performance concepts to design objectives
Environmental management systems - General guidelines on principles, systems and support techniques
Document History
Revises:
Revised By:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS