ASTM E1837-96

Standard Test Method to Determine Efficacy of Disinfection Processes for Reusable Medical Devices (Simulated Use Test)


This test method is intended to describe a procedure for testing the effectiveness of a disinfection process for reprocessing usable medical devices when it is tested with a challenge of vegetative cells including mycobacteria. Disinfection normally deals with testing activity against vegetative cells of bacteria, viruses, and fungi. Since this test method is process oriented, the user may wish to examine a variety of test organisms. 1.2 This test method is designed to provide a reproducible procedure to verify the effectiveness of a previously validated disinfectant or disinfection procedure for reusable medical instruments and devices. 1.3 this test method is not meant to define the effectiveness of or validation of the particular disinfection process used or its kinetics, but rather, it is devised to confirm the effectiveness of the disinfection process by simulating use situations with a particular test process using medical devices and instruments. Either manual or machine reprocessing can be tested. 1.4 this test method is intended for use with reusable cleaned and previously sterilized or disinfected (high level) medical instruments and devices. Endoscoped are described in this test method as a worst-case example for contamination and sampling. The selected sterilization or disinfectionprocesses, or both, should have been validated previously, as well as the effectiveness of rinsing for residual sterilant/disinfectant removal determined. 1.5 An inoculum with high numbers of selected microorganisms is applied to both test and control, cleaned and sterilized, or disinfected medical instruments. Strains of microorganisms with a recorded resistance to disinfectants are used to contaminate the instrument sites known or suspected to be the most difficult to reprocess. 1.6 It is impractical to test for recovery of survivors by immersion of some instruments, for example, endoscopes or some laproscopic instruments, in growth medium because of complexity, size, difficulty in long term incubation, or deterious effects resulting from incubation. Elution of organisms from the inoculated surfaces , therefore, may be performed to estimate the number of recoverable organisms. Immersion can be used for smaller instruments. 1.7 Control instruments are inoculated in the same manner as the test instruments and elution or immersion methods are performed to determine the number of organisms recoverable from the instrument. For channeled devides, such as endoscopes testing, the number of organisms recoverable from the instrument (inside and outside) will serve as the initial control count. It is expected that some fraction of the number of organisms inoculated will be lost in the process of inoculation/drying. 1.8 A testing procedure can be performed on a complete reprocessing cycle or can be limited to just the cleaning or disinfection portions of the cycle whether reprocessing is done in a machine or manually. 1.9 After the test cycle has been completed, remaining inoculated bacteria will be recovered from test instruments using the same elution procedures as for the control instruments. 1.10 Efficacy of a disinfection cycle or reprocessing cycle, or any part thereof, may be determined by comparison of the number of microorganisms recovered from the control instrument (initial recoverable control unit) to the recovery determined for the test instruments. 1.11 A knowledge of microbiological techniques is required to conduct these procedures. 1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


CONTENT PROVIDER
ASTM International [astm]

Others Also Bought
Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices
Standard Guide for Methods of Extraction of Test Soils for the Validation of Cleaning Methods for Reusable Medical ...
Standard Guide for Application of Test Soils for the Validation of Cleaning Methods for Reusable Medical Devi ...
Document History
We have no document history for this standard.
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.