ASTM E539-11

Standard Test Method for Analysis of Titanium Alloys by X-Ray Fluorescence Spectrometry

1.1 This test method covers the X-ray fluorescence analysis of titanium alloys for the following elements in the ranges indicated:

ElementMass Fraction Range, %
Aluminum0.041 to 8.00
Chromium0.013 to 4.00
Copper0.015 to 0.60
Iron0.023 to 2.00
Manganese0.003 to 9.50
Molybdenum0.005 to 4.00
Nickel0.005 to 0.80
Niobium0.004 to 7.50
Palladium0.014 to 0.200
Ruthenium0.019 to 0.050
Silicon0.014 to 0.15
Tin0.017 to 3.00
Vanadium0.017 to 15.50
Yttrium0.0011 to 0.0100
Zirconium0.007 to 4.00

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.


Content Provider
ASTM International [astm]


Others Also Bought

Standard Specification for Unalloyed Titanium, for Surgical Implant Applications (UNS R50250, UNS R50400, UNS ...
Document History
Revises:
Revised By:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS