Most recent

ASTM F2884-21

Standard Guide for Pre-clinical in vivo Evaluation of Spinal Fusion


1.1This guide covers general guidelines for the pre-clinical in vivo assessment of tissue-engineered medical products (TEMPs) intended to repair or regenerate bone in an interbody and/or posterolateral spinal environment. TEMPs included in this guide may be composed of, but are not limited to, natural or synthetic biomaterials or composites thereof, and may contain cells or biologically active agents such as growth factors, synthetic peptides, plasmids, or cDNA. The models described in this document represent a stringent test of a material's ability to induce and/or augment bone growth in the spinal environment.

1.2While clinically TEMPs may be combined with hardware for initial stabilization or other purposes, the focus of this guide is on the appropriateness of the animal model chosen and evaluation of the TEMP-induced repair and as such does not focus on issues of components or constructs.

1.3Guidelines include a description and rationale of various animal models for the in vivo assessment of the TEMP. The animal models utilize a range of species including rat (murine), rabbit (lapine), dog (canine), goat (caprine), pig (porcine), sheep (ovine), and non-human primate (primates). Outcome measures include in vivo assessments based on radiographic, histologic, and CT imaging as well as subsequent in vitro assessments of the repair, including histologic analyses and mechanical testing. All methods are described briefly and referenced. The user should refer to specific test methods for additional detail.

1.4This guide is not intended to include the testing of raw materials, preparation of biomaterials, sterilization, or packaging of the product. ASTM standards for these steps are available in Referenced Documents (Section 2).

1.5The use of any of the methods included in this guide may not produce a result that is consistent with clinical performance in one or more specific applications.

1.6Other pre-clinical methods may also be appropriate, and this guide is not meant to exclude such methods. The material must be suitable for its intended purpose. Additional biological testing in this regard would be required.

1.7The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.9This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.


CONTENT PROVIDER
ASTM International [astm]

Document History
We have no document history for this standard.
Included in Packages
This standard is also available in these packages:
Amendments & Corrections