Historical

ASTM F2927-12

Standard Test Method for Door Systems Subject to Airblast Loadings


1.1 This test method identifies the standard procedures that shall be followed when utilizing either a shock tube or a controlled open-air explosion to evaluate the blast capacity of a door system. This test method is designed for all types of swinging doors, including single and double doors construction. This method is used to test complete door assemblies. A door assembly includes the door panel(s), latching hardware, hinges, post mullion (if applicable), frame and frame connection to a rigid reaction structure. The door panel(s) may also contain one or more integral vision lites (glazing systems). The glazing system may include, but not be limited to those fabricated from monolithic glass, laminated glass, plastic, glass-clad plastics, glass/plastic glazing materials, and filmed-backed glass. The results gathered from this method can be used for door installations in non-rigid wall openings. The test method may be adapted to horizontal sliding and vertical-lift doors.

1.2 The scaled range or standoff of the charge shall be 1 m (3 ft, 3 in.) or greater from the specimen in order to reduce or eliminate any punching effect the blast may have on the specimen. A charge-in-contact blast test is not covered by this method.