Historical
ANSI Z83.26-2014/CSA 2.37-2014
ANSI Z83.26-2014/CSA 2.37-2014 - Gas-fired outdoor infrared patio heaters
Preface
This is the second edition of ANSI Z83.26 / CSA 2.37, Gas-fired outdoor infrared patio heaters. It supersedes the previous edition published in 2007.Scope
1.1 This Standard applies to newly produced gas-fired outdoor infrared patio heaters (see Clause 3, Definitions) hereinafter referred to as heaters or appliances, constructed entirely of new, unused parts and materials. Patio heaters are for use with: a) natural gas; and b) liquefied petroleum (propane) gases. 1.2 The heaters covered by this Standard are intended for installation in and heating of residential or nonresidential spaces (see Clause 3, Definitions). 1.3 Infrared patio heaters may be suspended overhead, angle mounted overhead, wall mounted, floor mounted, or for tabletop use. 1.4 Patio heaters intended for tabletop use shall be limited to input ratings of 15,000 Btu/hr (4 396 W) or less. 1.5 Infrared patio heaters may be for connection to: a) a fixed fuel piping system operating at inlet gas pressures not exceeding 1/2 psi (3.5kPa); or b) an integral self-contained liquefied petroleum (propane) gas supply system, provided the appliance incorporates mounting means for the attachment of a maximum of one cylinder limited to a maximum of 20 lb (9.1 kg) of fuel operating at regulated outlet:- i) pressure not exceeding 11 in wc (2.74 kPa); or ii) pressures in excess of 11 in wc (2.74 kPa) but not greater than 5 psi (34.5 kPa).
CSA America, Inc. [csa]