B52HB-16 - A practical handbook for implementing CSA B52-13, Mechanical refrigeration code
Preface
This is the second edition of CSA B52 HB, A practical handbook for implementing CSA B52-13, Mechanical refrigeration code. The primary objective of this handbook is to provide both novice and experienced users of CSA B52 with a concise, user-friendly guide to understanding and implementing the requirements of CSA B52. The B52 Code, which originated in 1939, has been regularly updated throughout the years and is now in its eleventh edition. This handbook also briefly describes the evolution of CSA B52, touching on the Code’s development process, updates and interpretations, and the relationship between the Code and jurisdictional regulations. Changes in the CSA B52-13 Standard are reflected in this edition of the handbook. As society has been advocating the change to natural refrigerants in order to preserve the environment, there are many safety issues which must be addressed. This version of the CSA B52 handbook will provide many of the recommended minimum safety protocols to be adhered to, in order to avoid issues. Many of the changes along with an explanation are as follows: a) Clause 3 has been updated to add the following definitions:- i) automated control; ii) fade-out vessel; iii) gas cooler; iv) manual control; v) pressure-regulating relief valve; vi) primary refrigerant; vii) secondary refrigerant; viii) subcritical; ix) subcritical system; x) systems; xi) supercritical; xii) thermal relief device (or thermal expansion relief device); xiii) transcritical system; and xiv) triple point;
- i) renumbering of Clauses 7.2.3.1.1, 7.2.3.1.2, and 7.2.3.3 of the 2005 edition; and ii) the addition of Clauses 7.2.3.2, 7.2.3.2.1, and 7.2.3.2.2;
Scope of CSA B52
The scope of CSA B52 is to provide minimum requirements for the design, construction, installation, inspection and maintenance of all mechanical refrigeration systems, as provided for by provincial and territorial acts, to minimize the risk of human injury. The Code applies to all refrigeration systems installed subsequent to its jurisdictional adoption, whether in new or existing premises, to systems that undergo a substitution of refrigerant, and to parts of a refrigeration system that are replaced in, or added to, refrigeration systems installed prior to its adoption. The word adoption refers to the date a jurisdiction adopts the Code, and so not necessarily to the year in which the Code was published.Content Provider
CSA America, Inc. [csa]