Most recent

CSA B64 SERIES-2026

Backflow preventers and vacuum breakers

Preface This is the eighth edition of the CSA B64 Series, Backflow preventers and vacuum breakers . It supersedes the previous editions, published in 2021, 2011, 2007, 2001, 1994, 1988, and 1976. This edition consists of the following Standards: • CSA B64.0, Definitions, general requirements, and test methods for vacuum breakers and backflow preventers; • CSA B64.1.1, Atmospheric vacuum breakers (AVB); • CSA B64.1.2, Pressure vacuum breakers (PVB); • CSA B64.1.3, Spill-resistant pressure vacuum breakers (SRPVB); • CSA B64.1.4, Vacuum breaker, air space type (ASVB); • CSA B64.2, Hose connection vacuum breakers (HCVB); • CSA B64.2.1, Hose connection vacuum breakers (HCVB) with manual draining feature; • CSA B64.2.1.1, Hose connection dual check vacuum breakers (HCDVB); • CSA B64.2.2, Hose connection vacuum breakers (HCVB) with automatic draining feature; • CSA B64.3, Dual check valve backflow preventers with atmospheric port (DCAP); • CSA B64.3.1, Dual check valve backflow preventers with atmospheric port for carbonators (DCAPC); • CSA B64.5, Double check valve (DCVA) backflow preventers; • CSA B64.6, Dual check valve (DuC) backflow preventers; • CSA B64.6.1, Dual check valve backflow preventers for fire protection systems (DuCF); • CSA B64.7, Laboratory faucet vacuum breakers (LFVB); • CSA B64.8, Dual check valve backflow preventers with intermediate vent (DuCV); and • CSA B64.9, Single check valve backflow preventers for fire protection systems (SCVAF). The following are the major changes to this edition: • Removal of CSA B64.4, Reduced pressure principle (RP) backflow preventers; • removal of CSA B64.4.1, Reduced pressure principle backflow preventers for fire protection systems (RPF); • removal of CSA B64.5.1, Double check valve backflow preventers for fire protection systems (DCVAF); • clarification of back siphonage test in CSA B64.6; and • addition of the CSA B64.5.1 and CSA B64.5 requirements referenced in CSA B64.9 directly into CSA B64.9. These Standards are considered suitable for use for conformity assessment within the stated scopes of the Standards. These Standards was prepared by the Technical Committee on Backflow Preventers and Water Pressure Reducing Valves, under the jurisdiction of the Strategic Steering Committee on Construction and Civil Infrastructure, and has been formally approved by the Technical Committee. These Standards have been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. They have been published as National Standards of Canada by CSA Group. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.0:26 - Definitions, general requirements, and test methods for vacuum breakers and backflow preventers Scope 1.1 Scope of the CSA B64 Series The CSA B64 Series covers vacuum breakers and backflow preventers that are used in potable water supply systems to prevent cross-connections. 1.2 Scope of this Standard This Standard specifies definitions, general requirements, test methods, markings, and instructions that are common to some or all of the Standards in the CSA B64 Series. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.1.1:26 - Atmospheric vacuum breakers (AVB) Scope 1.1 General This Standard covers atmospheric vacuum breakers (AVB). ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.1.2:26 - Pressure vacuum breakers (PVB) Scope 1.1 General This Standard covers pressure vacuum breakers (PVB). ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.1.3:26 - Spill-resistant pressure vacuum breakers (SRPVB) Scope 1.1 General This Standard covers spill-resistant pressure vacuum breakers (SRPVB). ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.1.4:26 - Vacuum breaker, air space type (ASVB) Scope 1.1 General This Standard covers manufactured vacuum breakers, air space type (ASVB). ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.2:26 - Hose connection vacuum breakers (HCVB) Scope 1.1 General This Standard covers hose connection vacuum breakers (HCVB). ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.2.1:26 - Hose connection vacuum breakers (HCVB) with manual draining feature Scope 1.1 General This Standard covers hose connection vacuum breakers (HCVBs) that incorporate a draining feature that requires manual operation. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.2.1.1:26 - Hose connection dual check vacuum breakers (HCDVB) Scope 1.1 General This Standard covers hose connection vacuum breakers that have two check valves (HCDVB) and that incorporate a draining feature that requires manual operation. The second (downstream) check valve is field-testable. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.2.2:26 - Hose connection vacuum breakers (HCVB) with automatic draining feature Scope 1.1 General This Standard covers hose connection vacuum breakers (HCVB) that incorporate an automatic draining feature that does not require manual operation. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.3:26 - Dual check valve backflow preventers with atmospheric port (DCAP) Scope 1.1 General This Standard covers dual check valve backflow preventers with an atmospheric port (DCAP) ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.3.1:26 - Dual check valve backflow preventers with atmospheric port for carbonators (DCAPC) Scope 1.1 General This Standard covers dual check valve backflow preventers with an atmospheric port for carbonators (DCAPC). ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.5:26 - Double check valve (DCVA) backflow preventers Scope 1.1 General This Standard covers double check valve (DCVA) backflow preventers. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.6:26 - Dual check valve (DuC) backflow preventers Scope 1.1 General This Standard covers dual check valve (DuC) backflow preventers. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.6.1:26 - Dual check valve backflow preventers for fire protection systems (DuCF) Scope 1.1 General This Standard covers dual check valve backflow preventers designed for use in fire protection systems (DuCF). ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.7:26 - Laboratory faucet vacuum breakers (LFVB) Scope 1.1 General This Standard covers vacuum breakers for use on laboratory faucets. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.8:26 - Dual check valve backflow preventers with intermediate vent (DuCV) Scope 1.1 General This Standard covers dual check valve backflow preventers with an intermediate vent (DuCV). Note: These devices are designed to be used on individual outlets or appliances with flow rates of 0.25 L/s or less. ------------------------------------------------------------------------------------------------------------------------------------- CSA B64.9:26 - Single check valve backflow preventers for fire protection systems (SCVAF) Scope 1.1 General This Standard covers single check valve backflow preventers specifically designed for use in fire protection systems (SCVAF).

CONTENT PROVIDER
CSA America, Inc. [csa]

Included in Packages
This standard is not included in any packages.
Document History
Amendments & Corrections
We have no amendments or corrections for this standard.