Customer Service:
Mon - Fri: 8:30 am - 6 pm EST

 Most recent

CAN/CSA C191-2013 (R2018)

Performance of electric storage tank water heaters for domestic hot water service

A revision was published as notification that this is now a National Standard of Canada.

To download any revisions and/or register for email notification of future revisions click here

Preface

This is the fifth edition of CSA C191, Performance of electric storage tank water heaters for domestic hot water service. It supersedes the previous editions, published in 2004 and 2000 under the title, Performance of Electric Storage Tank Water Heaters for Household Service.

Technological changes since the publication of the previous edition of this Standard have led to the updating of clauses dealing with element Watts densities, test procedures, and standby loss levels. The wooden testing platform has been replaced with concrete.

CSA acknowledges that the development of this Standard was made possible, in part, by the financial support of BC Hydro, the Canadian Electricity Association, Conserve Nova Scotia, Hydro-QuΘbec, Manitoba Hydro, Natural Resources Canada, and the Ontario Ministry of Energy.

This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.

Scope

1.1 General

This Standard specifies requirements related to hot water delivery, minimum standby performance, heater element ratings, and marking of electric storage tank water heaters.

1.2 Tank capacity

This Standard applies to stationary storage tank water heaters that have a rated capacity of 50 to 454 L (11 to 100 gal) and are intended for use with pressure systems in residential premises and similar locations. For convenience, the term "water heater" is used in this Standard to refer to such heaters.

1.3 Mandatory language

In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements. Legends to equations and figures are considered requirements.

1.4 Units of measurement

The values given in SI (metric) units are the standard. The values given in parentheses are for information only. All measurements in gallons refer to imperial gallons.


Content Provider
CSA America, Inc. [csa]


Others Also Bought

ANSI Z21.94-2006/CSA 6.31-2006 (R2016) - Automatic Flammable Vapor Sensor Systems and Components
Gas water heaters, volume I, storage water heaters with input ratings of 75,000 Btu per hour or less
Gas-fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating ...
Document History
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.