CSA C22.2 No. 236-2015
C22.2 NO. 236-15 - Heating and cooling equipment (Bi-national standard with UL 1995)
Preface
This is the harmonized CSA Group and UL standard for Heating and Cooling Equipment. It is the fifth edition of CSA C22.2 No. 236 and the fifth edition of UL 1995. This edition of CSA C22.2 No. 236 and UL 1995 supersedes the previous editions published in 1995, 1990, 2005 and 2011.Scope
1.1 These requirements apply to the following stationary equipment for use in nonhazardous locations rated greater than 600 volts up to 7200 V, and remote control assemblies for such equipment:- a) Heat pumps, for heating and cooling with or without factory, or field-installed electric resistance heaters, or hot water or steam heating coils; b) Air conditioners for cooling with or without factory, or field-installed electric resistance heaters, or hot water or steam heating coils; c) Liquid chillers and compressor-evaporator or liquid chiller assemblies intended for use with remote condensers; d) Add-on heat pumps for comfort heating or heating and cooling; and e) Heat pump water heaters and refrigerant desuperheaters, and packaged heat pump water heaters consisting of a heat pump water heater and an associated storage tank; Note: The above equipment rated 600 V or less are covered by the scope of ANCE/CSA/UL 60335-2-40.
- a) Cooling portion and associated components of combination heating and cooling equipment employing gas-, oil-, or gas-oil-fired heating means. However, the requirements for the construction and performance of the gas-, oil-, or gas-oil-fired heating means, and their associated components, shall conform to the particular standards covering such heating equipment and components; b) Condensing units intended for connection to a remote nonspecified evaporator and compressor units intended for connection to a remote nonspecified evaporator and condenser; and c) Room fan heater units, central heating furnaces, and similar fixed electric space heating for comfort heating. Note: The equipment mentioned in Clauses 1.3, 1.4, 1.5, 1.6, 1.7 and 1.13 are rated 7200 V or less, single or 3-phase. These products are not covered by the scope of ANCE/CSA/UL 60335-2-40.
- a) The heat pump and furnace are intended to operate simultaneously during heating operation except as noted in the Exception to Clause 26.17; or b) The refrigerant coil is intended to be mounted upstream (return air side) of the furnace.
- Note 1: Requirements for the installation of units designed to be connected to air duct systems are also included in codes such as the BOCA Basic National Mechanical Code, the ICC’s Standard Mechanical Code, and the ICC’s Uniform Mechanical Code. Note 2: Coolant distribution equipment are intended for use in an information technology room (ITE) that comples with NFPA 75.
- a) “General Requirements”, Clause 3, and “Construction Details”, Clause 4 (refer to Clauses 2 through 36 of this standard); b) “Marking”, Clause 5 (refer to Clauses 43, 44, and 45 of this standard); c) “Tests”, Clause 6 (refer to Clauses 46 through 79 of this standard).