Most recent

IEC 60512-11-1 Ed. 2.0 b:2019

Connectors for electrical and electronic equipment - Tests and measurements - Part 11-1: Climatic tests - Test 11a - Climatic sequence

IEC 60512-11-1:2019 when required by the detail (product) specification, is used for testing connectors within the scope of IEC technical committee 48. This test may also be used for similar devices (i.e. when the degradation mechanisms are the same) when specified in a detail (product) specification.
 The object of this test is to define a standard test method to assess the ability of connectors to function in a specified manner, in a specified environment which might be encountered during normal use, including storage.
 This document provides a standard composite test method for determining the suitability of connectors when subjected to environmental conditions consisting of a sequence of temperature, humidity and, where required, low air pressure environmental stresses.
 Key words: Connectors, Climatic Tests

CONTENT PROVIDER
International Electrotechnical Commission [iec]

Others Also Bought
Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
Environmental testing - Part 2-58: Tests - Test Td: Test methods for solderability, resistance to dissolution of ...
Environmental testing - Part 2-69: Tests - Test Te/Tc: Solderability testing of electronic components and printed ...
Included in Packages
This standard is not included in any packages.
Document History
Amendments & Corrections
We have no amendments or corrections for this standard.