Customer Service:
Mon - Fri: 8:30 am - 6 pm EST

 Most recent

ISO 15171-2:2016

Connections for fluid power and general use - Hydraulic couplings for diagnostic purposes - Part 2: Coupling with M16 x 2 end for connection under pressure

ISO 15171-2:2016 specifies dimensions, performance requirements, and test procedures for diagnostic couplings with an M16 × 2 connection end that can be connected under pressure without tools to a maximum pressure of 40 MPa (400 bar) providing following stud ends:

? ISO 6149‑2 ? M14 × 1,5;

? ISO 9974‑2 ? M14 × 1,5;

? ISO 1179‑2 ? G 1/4;

? ISO 11926‑2 ? 7/16-20 UNF.

The dimensions of the coupler counterpart are specified. The coupling is designed for use in hydraulic systems that use mineral oils.

NOTE The use of this coupling with fluids other than mineral oil requires an agreement between the supplier and the purchaser.

Couplings in accordance with this part of ISO 15171 may be used at a maximum working pressure of 63 MPa (630 bar). The working pressure depends upon the materials, design, working conditions, application, etc.


Content Provider
International Organization for Standardization [iso]


Others Also Bought

Connections for fluid power and general use -- Hydraulic couplings for diagnostic purposes -- Part 1: Coupling ...
Connectors for fluid power and general use - Designation and nomenclature
Hydraulic fluid power - Dimensions and requirements for screw-to-connect quick-action couplings for use at a pressure ...
Document History
Revises:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.