Historical

SAE AMS 2630C-2010 (SAE AMS2630C-2010)

Inspection, Ultrasonic Product Over 0.5 inch (12.7 mm) Thick


This specification covers procedures for ultrasonic inspection, by pulse-echo procedure, of flat, rectangular, round, cylindrical, and contoured products having a thickness or cross-sectional dimension greater than 0.50 inch (12.7 mm), using either contact or immersion methods, and using the longitudinal-wave or shear-wave modes or combinations of the two, as necessary. This specification may apply to testing finished machined parts provided the parts can meet the basic testability requirements, such as size, contour, metallurgical structure, and thickness. Parts with section thickness both over 0.50 inch (12.7 mm) and 0.5 inch (12.7 mm) and under may be tested using the procedure and AMS 2632, as applicable. This procedure has been used typically for locating and defining internal defects such as cracks, voids, laminations, and other structural discontinuities which may or may not be exposed to the surface, but usage is not limited to such applications.


CONTENT PROVIDER
Society of Automotive Engineers [sae]

Others Also Bought
Inspection, Ultrasonic, Wrought Metals, Process for ( Reaffirmed: Sep 2005 )
Nickel Alloy, Corrosion and Heat-Resistant, Bars, Forgings, and Rings 52.5Ni 19Cr 3.0Mo 5.1Cb (Nb) 0.90Ti 0.50Al ...
Document History
Included in Packages
This standard is not included in any packages.
Amendments & Corrections