Most recent

UL 60730-1 Ed. 6-2024

Automatic Electrical Controls - Part 1: General Requirements - Published Date: October 31, 2024

In general, this part of IEC 60730 applies to automatic  ELECTRICAL CONTROLS  for use in, on, or in association with equipment for household and similar use. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. NOTE 1 Throughout this standard the word "equipment" means "appliance and equipment."  EXAMPLE 1  CONTROLS  for appliances within the scope of IEC 60335. This International Standard is applicable to  CONTROLS  for building automation within the scope of ISO 16484. This standard also applies to automatic  ELECTRICAL CONTROLS  for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. EXAMPLE 2  CONTROLS  for commercial catering, heating and air-conditioning equipment. This standard is also applicable to individual  CONTROLS  utilized as part of a CONTROL  system or CONTROLS  which are mechanically integral with multifunctional CONTROLS  having non-electrical outputs. EXAMPLE 3 Independently mounted water valves,  CONTROLS  in smart grid systems and CONTROLS  for building automation systems within the scope of ISO 16484-2. This standard is also applicable to relays when used as  CONTROLS  for IEC 60335 appliances. Additional requirements for the safety and OPERATING VALUES  of relays when used as CONTROLS  for IEC 60335 appliances are contained in Annex U. NOTE 2 These requirements are referred to in the scope of IEC 61810-1.  NOTE 3 This standard is intended to be used for the testing of any stand-alone relay which is intended to be used as a  CONTROL  of an appliance according to IEC 60335-1. It is not intended to be used for any other stand-alone relay, or to replace the IEC 61810 series of standards. This standard does not apply to automatic  ELECTRICAL CONTROLS  intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. This standard applies to  CONTROLS  powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V.  1 1.1 This International Standard applies to the inherent safety, to the  OPERATING VALUES  , OPERATING TIMES  , and OPERATING SEQUENCES  where such are associated with equipment safety, and to the testing of automatic ELECTRICAL CONTROL  devices used in, or in association with, equipment. This standard applies to  CONTROLS  using THERMISTORS  , see also Annex J. This standard is also applicable to the  FUNCTIONAL SAFETY  of LOW COMPLEXITY SAFETY RELATED SYSTEMS  and CONTROLS  .  1 1.2 This standard applies to automatic  ELECTRICAL CONTROLS  , mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof.  1 1.3 This standard applies to starting relays, which are a specific type of automatic  ELECTRICAL CONTROL  , intended to switch the starting winding of a motor. Such CONTROLS  may be built into, or be separate from, the motor.  1 1.4 This standard applies to  MANUAL CONTROLS  when such are electrically and/or mechanically integral with AUTOMATIC CONTROLS  . NOTE Requirements for manual switches not forming part of an  AUTOMATIC CONTROL  are contained in IEC 61058-1.  1 1.5 This standard applies to a.c. or d.c. powered  CONTROLS  with a rated voltage not exceeding 690 V a.c. or 600 V d.c.  1 1.6 This standard does not take into account the  RESPONSE VALUE  of an AUTOMATIC ACTION  of a CONTROL  , if such a RESPONSE VALUE  is dependent upon the method of mounting the CONTROL  in the equipment. Where a RESPONSE VALUE  is of significant purpose for the protection of the USER  , or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer shall apply.  1 1.7 This standard applies also to  CONTROLS  incorporating ELECTRONIC DEVICES  , requirements for which are contained in Annex H.  This standard applies to discrete  THERMISTORS  and also to controls using NTC  or PTC  THERMISTORS  , requirements for which are contained in Annex J  1 1.8 This standard applies also to  CONTROLS  using NTC  or PTC  THERMISTORS  , requirements for which are contained in Annex J.  1 1.9 This standard applies to the electrical and  FUNCTIONAL SAFETY  of CONTROLS  capable of receiving and responding to communications signals, including signals for power billing rate and demand response. The signals may be transmitted to or received from external units being part of the  CONTROL  (wired), or to and from external units which are not part of the CONTROL  (wireless) under test.  1 1.10 This standard does not address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the  CONTROL SYSTEM  .   CONTROLS  intended to be installed in air handling spaces or in other environmental air space (plenums) are covered under the scope of this standard.

CONTENT PROVIDER
Underwriters Laboratories [ul]

Included in Packages
This standard is not included in any packages.
Document History
Amendments & Corrections
We have no amendments or corrections for this standard.