ANSI/ASSE 1049-2009

Performance Requirements for Individual and Branch Type Air Admittance Valves for Chemical Waste Systems

AAVCs are devices used in chemical waste systems to prevent the siphonage of trap seals. These devices do not relieve back pressure; they only allow air to enter the system. They are designed to be used for individual fixtures or for a horizontal branch serving multiple fixtures. When the devices are installed in a building, there shall be at least 1 open vent terminal to relieve positive pressure which extends to the atmosphere outside of the building serving the same building drain on which these devices are installed. These devices shall not be installed in an area with a constant air pressure differential greater than ±0.3 inches (7.6 mm) WC.


Content Provider
American Society of Sanitary Engineering [asse-sanitary]


Document History
Revised By:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.