ANSI/ASHRAE 62.1-2007

Ventilation for Acceptable Indoor Air Quality (Includes Errata sheet and Interpretation 02 to ANSI/ASHRAE Standard 62.1-2007)

1 This standard applies to all spaces intended for human occupancy except those within single-family houses, multifamily structures of three stories or fewer above grade, vehicles, and aircraft.

2 This standard defines requirements for ventilation and air-cleaning system design, installation, commissioning, and operation and maintenance.

3 Additional requirements for laboratory, industrial, health care, and other spaces may be dictated by workplace and other standards, as well as by the processes occurring within the space.

4 Although the standard may be applied to both new and existing buildings, the provisions of this standard are not intended to be applied retroactively when the standard is used as a mandatory regulation or code.

5 This standard does not prescribe specific ventilation rate requirements for spaces that contain smoking or that do not meet the requirements in the standard for separation from spaces that contain smoking.

6 Ventilation requirements of this standard are based on chemical, physical, and biological contaminants that can affect air quality.

7 Consideration or control of thermal comfort is not included.

8 This standard contains requirements, in addition to ventilation, related to certain sources, including outdoor air, construction processes, moisture, and biological growth.

9 Acceptable indoor air quality may not be achieved in all buildings meeting the requirements of this standard for one or more of the following reasons:

  • a. because of the diversity of sources and contaminants in indoor air;
  • b. because of the many other factors that may affect occupant perception and acceptance of indoor air quality, such as air temperature, humidity, noise, lighting, and psychological stress;
  • c. because of the range of susceptibility in the population; and
  • d. because outdoor air brought into the building may be unacceptable or may not be adequately cleaned.


Content Provider
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. [ashrae]


Others Also Bought

Thermal Environmental Conditions for Human Occupancy
Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings
Energy Standard for Buildings Except Low-Rise Residential Buildings, I-P Edition
Document History
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS