AWWA meter standards cover the C700 series, which cover a variety of water meter types including displacement, turbine, compound, fire service, propeller, multi- and single-jet, fluid-oscillator, and ultrasonic types. In addition, the calibration methods and verifications for meters in different conduits and magnetized flowmeters for residential and commercial buildings are addressed.
The purpose of this standard is to provide the minimum requirements for cold-water meters—displacement type, metal alloy main case, including materials and design.
The purpose of this standard is to provide the minimum requirements for cold-water turbine-type meters, including materials and design.
The purpose of this standard is to provide the minimum requirements for compound-type cold-water meters, including materials and design.
The purpose of this standard is to provide the minimum requirements for cold-water meters—fire-service type.
The purpose of this standard is to provide the minimum requirements for propeller-type meters for waterworks applications.
The purpose of this standard is to provide the minimum requirements for encoder-type remote-registration systems for cold-water meters, including fabrication and assembly.
The purpose of this standard is to provide the minimum requirements for multijet-type cold-water meters, including materials and design.
The purpose of this standard is to provide the minimum requirements for cold-water meters—displacement type, plastic main case, including materials and design.
The purpose of this standard is to provide the minimum requirements for cold-water singlejet meters, including material and design.
The purpose of this standard is to provide the minimum requirements for cold-water meters—fluidic-oscillator type, including materials and design.
The purpose of this standard is to provide the minimum requirements for cold-water meters for residential fire sprinkler applications that meet the requirements of NFPA 13D in one- and two-family dwellings and manufactured homes, in sizes 3/4 in. (20 mm) through 2 in. (50 mm), including materials and design.
The purpose of this standard is to provide the minimum requirements for potable cold-water meters of the electromagnetic and ultrasonic type, in sizes 1/2 in. (13 mm) through 20 in. (500 mm), for revenue applications.
The purpose of this standard is to provide the minimum requirements for transit-time flowmeters, including components, performance, calibration, and verification.
The purpose of this document is to review magnetic inductive flowmeter (magmeter) principles of operation, calibration, and selection. Magnetic inductive flowmeters or electromagnetic flowmeters are commonly called magmeters. The flowmeter referenced in this standard will be called a magmeter or magnetic flowmeter interchangeably. Magmeters are available in wafer style and threaded and flanged-end connection designs. These spool/tube design flowmeters are most commonly used in the water industry. This standard will focus on magmeters of this design. This standard does not apply to the insertion type of magmeter. This standard does not address specific issues where a magmeter would be used in revenue service.