Historical
ANSI/ASA S12.57-2002 (R 2007) / ISO 3747:2000
Standard Acoustics - Determination of sound power levels of noise sources using sound pressure - Comparison method in situ
This Nationally Adopted International Standard specifies a method for determining the sound power levels of sound sources in situ, especially if non-movable. A comparison method is used and all measurements are carried out in octave bands. The measurement uncertainty depends on the test environment. The measurement uncertainty is evaluated by comparing with an indicator describing the spatial sound distribution. The accuracy will either be that of an engineering method or a survey method.
The sound power level of the source under test is calculated form the measured values of the sound pressure levels produced at specified measurement points by the source and by a reference sound source, respectively. The sound power level is calculated using the calibrated values of the reference sound source and the differences between the values obtained with the source under test and those of the reference sound source. All calculations are carried out in octave bands, from which the A-weighted sound power level is determined.
Content Provider
Acoustical Society of America [asa]