Non-destructive testing. Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing. Pinhole camera radiographic method (British Standard)

This European Standard specifies a method for the measurement of focal spot dimensions above 0,2 mm of X-ray systems up to and including 500 kV tube voltage by means of the pinhole camera radiographic method. The voltage applied for this measurement is restricted to 200 kV for visual film evaluation. The image quality and the resolution of X-ray images depend highly on the characteristics of the focal spot, in particular the size and the two dimensional intensity distribution. For the characterisation of commercial X-ray tube types (i.e. for advertising or trade) the specific values of Table A.1 are used.


Content Provider
British Standards Institution [bsi]


Others Also Bought

Non-destructive testing. Measurement and evaluation of the X-ray tube voltage. Voltage divider method (British ...
Specification for minimum requirements for industrial radiographic illuminators for non-destructive testing (British ...
Non-destructive testing. Characteristics of focal spots in industrial X-ray systems for use in non-destructive ...
Document History
Revises:
  • BS EN 12543-2:1999
Revised By:
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS