ISO/TS 21726:2019

Biological evaluation of medical devices - Application of the threshold of toxicological concern (TTC) for assessing biocompatibility of medical device constituents

This document describes the basis for, selection of, and general applicability of a threshold of toxicological concern (TTC) value for a constituent present in/on a medical device or released from a medical device. The TTC values in this document can be used for:

— comparing to a maximum concentration of an identified or unidentified constituent in an extract (see ISO 10993-18);

— supporting toxicological equivalence;

— comparing to a maximum exposure dose estimate of an identified constituent (see ISO 10993-17).

NOTE Constituent is defined in 3.1.

ISO 10993-18 specifies how to convert TTC (µg/d) into a concentration (µg/ml).

TTC is not applicable to constituents with adequate toxicity data for deriving a tolerable intake (TI) value (see ISO 10993-17).

The TTC values established in this document are protective for carcinogens, systemic toxicants, and reproductive toxicants (see Clause 5). This document does not include TTC values for other biological endpoints assessed as part of the biological evaluation of a medical device, per ISO 10993-1, for example:

— cytotoxicity;

— irritation;

— sensitization;

— hemocompatibility;

— material mediated pyrogenicity;

— local effects that occur in tissues at the site of contact between a medical device and the body (e.g. the observations from implantation studies).

The TTC values in this document do not apply to potential exposure via gas pathways of medical devices. For application of TTC for constituents present/released from these devices, see the ISO 18562 series.

The TTC values presented in this document are not applicable for the safety assessment of cohort of concern (see 5.3).


Content Provider
International Organization for Standardization [iso]


Others Also Bought

Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within ...
Biological evaluation of medical devices - Part 17: Establishment of allowable limits for leachable substances ...
Biological evaluation of medical devices - Part 23: Tests for irritation
Document History
We have no document history for this standard.
Included in Packages
This standard is not included in any packages.
Amendments & Corrections
We have no amendments or corrections for this standard.
ANSI Logo

As the voice of the U.S. standards and conformity assessment system, the American National Standards Institute (ANSI) empowers its members and constituents to strengthen the U.S. marketplace position in the global economy while helping to assure the safety and health of consumers and the protection of the environment.

CUSTOMER SERVICE
NEW YORK OFFICE
ANSI HEADQUARTERS